February 25, 2005 Document No. 38-12022 Rev. *G 18
CY8C21x23 Final Data Sheet 3. Electrical Specifications
3.3.4 DC Switch Mode Pump Specifications
The following table lists guaranteed maximum and minimum specifications for the voltage and temperature ranges: 4.75V to 5.25V
and -40°C ≤ T
A
≤ 85°C, 3.0V to 3.6V and -40°C ≤ T
A
≤ 85°C, or 2.4V to 3.0V and -40°C ≤ T
A
≤ 85°C, respectively. Typical parameters
apply to 5V, 3.3V, or 2.7V at 25°C and are for design guidance only.
Figure 3-2. Basic Switch Mode Pump Circuit
Table 3-10. DC Switch Mode Pump (SMP) Specifications
Symbol Description Min Typ Max Units Notes
V
PUMP5V
5V Output Voltage from Pump 4.75 5.0 5.25 V
Configuration of footnote.
a
Average, neglecting
ripple. SMP trip voltage is set to 5.0V.
V
PUMP3V
3.3V Output Voltage from Pump 3.00 3.25 3.60 V
Configuration of footnote.
a
Average, neglecting
ripple. SMP trip voltage is set to 3.25V.
V
PUMP2V
2.6V Output Voltage from Pump 2.45 2.55 2.80 V
Configuration of footnote.
a
Average, neglecting
ripple. SMP trip voltage is set to 2.55V.
I
PUMP
Available Output Current
V
BAT
= 1.8V, V
PUMP
= 5.0V
V
BAT
= 1.5V, V
PUMP
= 3.25V
V
BAT
= 1.3V, V
PUMP
= 2.55V
5
8
8
–
–
–
–
–
–
mA
mA
mA
Configuration of footnote.
a
SMP trip voltage is set to 5.0V.
SMP trip voltage is set to 3.25V.
SMP trip voltage is set to 2.55V.
V
BAT5V
Input Voltage Range from Battery 1.8 – 5.0 V
Configuration of footnote.
a
SMP trip voltage is
set to 5.0V.
V
BAT3V
Input Voltage Range from Battery 1.0 – 3.3 V
Configuration of footnote.
a
SMP trip voltage is
set to 3.25V.
V
BAT2V
Input Voltage Range from Battery 1.0 – 2.8 V
Configuration of footnote.
a
SMP trip voltage is
set to 2.55V.
V
BATSTART
Minimum Input Voltage from Battery to Start Pump 1.2 – – V
Configuration of footnote.
a
0
o
C ≤ T
A
≤ 100.
1.25V at T
A
= -40
o
C.
∆V
PUMP_Line
Line Regulation (over Vi range) – 5 – %V
O
Configuration of footnote.
a
V
O
is the “Vdd Value
for PUMP Trip” specified by the VM[2:0] setting
in the DC POR and LVD Specification, Table 3-
11 on page 19.
∆V
PUMP_Load
Load Regulation – 5 – %V
O
Configuration of footnote.
a
V
O
is the “Vdd Value
for PUMP Trip” specified by the VM[2:0] setting
in the DC POR and LVD Specification, Table 3-
11 on page 19.
∆V
PUMP_Ripple
Output Voltage Ripple (depends on cap/load) – 100 – mVpp
Configuration of footnote.
a
Load is 5 mA.
a. L
1
= 2 µH inductor, C
1
= 10 µF capacitor, D
1
= Schottky diode. See Figure 3-2.
E
3
Efficiency 35 50 – %
Configuration of footnote.
a
Load is 5 mA. SMP
trip voltage is set to 3.25V.
E
2
Efficiency 35 80 – % For I load = 1mA, V
PUMP
= 2.55V, V
BAT
= 1.3V,
10 uH inductor, 1 uF capacitor, and Schottky
diode.
F
PUMP
Switching Frequency – 1.3 – MHz
DC
PUMP
Switching Duty Cycle – 50 – %
Battery
C1
D1
+
PSoC
TM
Vdd
Vss
SM P
V
BAT
V
PUMP
L
1
Comments to this Manuals